Technical data | Ultra 3 SA - 90/4 | Ultra 3 SA - 100/5 |
---|---|---|
Voltage: | 230 V. single-phase | 230/400 V. three-phase | |
Motor: | 0,66 kW | 0,75 kW |
Max. delivery: | 4,6 m³/h | 4,6 m³/h |
Max. head: | 43,0 m | 54,0 m |
Suction side: | 1" female | 1" female |
Pressure side: | 1" female | 1" female |
Weight: | 9,6 kg | 12,2 kg |
Technical data: | Ultra 5 SA - 120/4 | Ultra 5 SA - 150/5 |
---|---|---|
Voltage: | 230 V. single-phase | 230/400 V. three-phase | |
Motor: | 0,9 kW | 1,1 kW |
Max. delivery: | 7,8 m³/h | 7,8 m³/h |
Max. head: | 44,5 m | 56,0 m |
Suction side: | 1" female | 1" female |
Pressure side: | 1" female | 1" female |
Weight: | 12,3 kg | 15,1 kg |
fully assembled, including membrane tank, pressure switch for pressure-dependent switching on and off, pressure gauge and flexible hose, wired ready to plug in
available in 230 V and 400 V:
Group U 3SA 100/5 - 20 l horizontal membrane tank - stainless steel |
Dimensions: (L x W x H) ca. 560 x 350 x 560 mm |
Group U 5SA 120/4 - 50 l horizontal membrane tank - stainless steel |
Dimensions: (L x W x H) ca. 710 x 380 x 690 mm |
Group U 5SA 150/5 - 100 l horizontal membrane tank - stainless steel |
Dimensions: (L x W x H) ca. 810 x 490 x 820 mm |
The integrated frequency inverter Epic for electronic speed control and constant pressure:
input: 230 Volt single-phase
output: 230/400 Volt three-phase
suitable for pumps up to 7,5 A
Note: Frequency controlled pumps should be installed with a diaphragm tank to avoid constant switching on and off (max. tank size = 10% of max. capacity).
Group Ultra SAt /8 l with a diaphragm tank and integrated frequency inverter Epic