The multistage pump ECOLOGIC 5" (AØ 131 mm) is equipped with a Franklin electric motor 230 Volt or 400 Volt, 50 Hz and is suitable for clear water. Equipped with or without float switch 0.5 m. Installation is possible horizontally and vertically . Stainless steel pump body, impellers and diffusers made of plastic. SV version with intake.
Technical data:
- Max. liquid temperature: 35°C
- Connection pressure side: 1 1/4" F
- Connection suction side with intake: 1 1/2" F
- No built-in check valve
- Cable length: 15 m (except execution SV with intake is supplied with a short cable end and can be renewed for an additional charge)
- Max. 20 starts per hour
- Insulation class B, protection IP 68
- The motor is cooled by the passing fluid.
- AC pumps: separate capacitor included in the delivery. Connection via DCP control box with built-in thermal protection is recommended.
- Three-phase pumps must be protected by a motor protection switch against overload, undervoltage or phase failure. AC pumps are protected with a thermal circuit breaker.
Type | Type | KW | A | A | Cap. | l/min | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 120 |
Mono-phase | Three-phase | | 230 V | 400 V | µF | m³/h | 0 | 0,6 | 1,2 | 1,8 | 2,4 | 3,0 | 3,6 | 4,2 | 4,8 | 5,4 | 7,2 |
| Head in m. |
2 E 75 M | 2 E 75 T | 0,75 | 5,7 | 2,1 | 35 | | 58 | 52 | 49 | 45 | 40 | 34 | 27 | 20 | | | |
2 E 110 M | 2 E 110 T | 1,10 | 8,6 | 2,9 | 40 | | 82 | 78 | 72 | 66 | 60 | 51 | 42 | 32 | | | |
4 E 150 M | 4 E 150 T | 1,50 | 10,6 | 3,8 | 50 | | 96 | | 88 | 84 | 81 | 77 | 73 | 68 | 63 | 57 | 30 |
- | 8 E 220 T | 2,20 | | 5,9 | | | 74 | | | | | | 68 | 66 | 64 | 63 | 58 |